Fridge and appliance runtime

Calculate power station runtime

Estimate hours for a refrigerator or other load from watt-hours, running watts, efficiency, reserve, and duty cycle.

Usable Wh ÷ average W= estimated hours

Enter your power needs

Start with the battery capacity and the appliance's running wattage.

Adjust assumptions
Estimated runtime7.7 hours

Under the assumptions shown below.

Conservative estimate
6.5 hours
Usable battery energy
765 Wh
Average appliance load
100 W
This is an estimate.

Temperature, battery condition, inverter losses, and appliance behavior affect actual runtime.

    What this calculator includes

    Rated capacity, inverter efficiency, battery reserve, appliance running watts, and optional duty cycle.

    What it cannot predict

    Startup compatibility, temperature effects, battery aging, firmware behavior, and exact appliance cycling.

    How should you read the runtime result?

    The result is a planning estimate for the inputs you enter. Rated watt-hours describe battery energy; watts describe appliance demand. Inverter losses and a reserve reduce the energy available to an AC load. A 1,000 Wh battery with 85% efficiency and a 10% reserve supplies an illustrative 765 Wh before the chosen reserve, so a continuous 100 W load gives 7.65 hours. These are arithmetic assumptions, not a measured product result.

    How do cycling appliances change the answer?

    A refrigerator compressor does not necessarily draw its running wattage throughout the day. Enter running watts with an observed duty cycle, or measured average watts with duty at 100%. Do not use average watts and then reduce them by the duty fraction again. Room conditions, opening the door, thermostat settings and defrost cycles make a short observation a limited basis for an outage plan.

    Why might a large battery still fail to run a load?

    Energy capacity cannot compensate for inadequate inverter output. Motor startup and concurrent appliances must fit the continuous and starting limits in the relevant manuals. The tool does not simulate startup duration, changing temperature, battery aging or an inverter's low-load overhead. Before relying on an estimate, check your own equipment and repeat a supervised run under representative conditions.

    What if you know hours but not battery capacity?

    Use the required power station size calculator to reverse the formula. It estimates rated Wh from target hours and measured load, with the same efficiency and reserve assumptions. For several appliances, list their energy separately and check which loads run at the same time. The outage worksheet helps keep energy and output decisions together.

    Method reviewed: 2026-10-19. All numerical examples are editorial illustrations.